1. Power-on/off procedures:
Power on: Close the power circuit breaker and turn on the key switch.
Power off: Turn off the industrial control computer system, turn off the key switch, and turn off the main
power supply.
Precautions: After powering on, perform the return-to-machine-origin operation, calibrate the cutting head,
and check the lens.
2. Laser:
Power on: Turn the key switch to "ON" and press the "START" button (it will normally light up).
Power off: Turn off the lead beam (red light) from the machine tool or laser panel.
After EMISSION (light valve), turn the key switch to the neutral position.
Note: Turn on the water chiller 5 minutes after powering on, and turn off the laser 5 minutes after turning
off the water chiller.
In winter, please strictly follow the laser's winter maintenance manual to avoid damage from freezing.
3. Regulated Power Supply:
Power On: Close the incoming circuit breaker and press the start button.
Power Off: Press the stop button and close the connecting circuit breaker.
Note: The working mode is in the automatic position.
4. Water Chiller:
Start-up: Turn the water chiller circuit breaker to "ON" and press the "START" button.
Stop-up: Press the "STOP" button and turn the water chiller circuit breaker to "OFF".
Precautions: Use low-temperature water at 27℃ and high-temperature water at 30℃. Replace distilled
water every 6 months and clean the filter screen promptly.
5. Air compressor:
To start: Close the power circuit breaker and toggle the switch to "ON".
To stop: Toggle the switch to "OFF" and disconnect the power circuit breaker.
Precautions: Loading pressure 1 MPa, unloading pressure 1.25 MPa, drain water daily from the valve
below the air tank on the machine body.
6. Refrigerated Dryer:
Power On: Press the switch (lights up normally)
Power Off: Turn off the switch (before turning it off, ensure the air valve stops flowing).
Note: The status window indicator will be in the green area.